  protection relays & controls ? 2013 littelfuse protection relays & controls littelfuse.com/fps phase ct phase ct gf ct phase ct l2 fps-ctu l1 fps-opi (control unit) (operator interface) feeder protectionCadvanced fps series feeder protection system 1 2 description the fps feeder protection system monitors voltage and current to provide a comprehensive package of 17 protective functions. the fps is a modular system with integrated protection, breaker control, metering, and data-logging functions. operator interface (fps-opi) g large, bright, 4 x 20 vacuum-fuorescent display g display metered values g access set points g powered by control unit g panel mount or attach directly to control unit g remote mounting (1.2 km or 4000 ft maximum loop length) g 1/2 din size g hazardous-location certifed control unit (fps-ctu) g current inputs5-a or 1-a secondary phase current transformers g voltage inputsup to 600 v without pts g earth-leakage input5-a or 1-a secondary or sensitive transformer g 8 digital inputs, 5 relay outputs, 1 analog input and output g 24-vdc supply for opi and rtd modules, and for digital inputs g irig-b time-code input g 1/2 din size, surface mount g rs-485 network communications (standard) g devicenet ? , profbus ? , or ethernet communications available 1 2 phase current transformers phase cts are required to detect phase currents. ground-fault current transformer zero-sequence current transformer detects ground-fault current. available with 5-a and 30-a primary ratings for low-level pickup. mps-rtd temperature input module optional module provides 8 inputs to connect pt100, ni100, ni120, and cu10 rtds. se-ip65cvr-m cover optional gasketed, transparent cover for limited access and ip65 protection for an operator interface module. b c d accessories a accessories requirement fps-opi-01-00 recommended se-ip65cvr-m optional phase cts required ground-fault ct recommended mps-rtd -01-00 optional 1 2 ordering number communications fps-ctu-01-00 rs-485 fps-ctu-02-00 rs-485 & devicenet ? fps-ctu-03-00 rs-485 & profbus ? FPS-CTU-04-00 rs-485 & ethernet ordering information simplifed circuit diagram b a rev: 4-a-050213 based on manual rev 0
protection relays & controls ? 2013 littelfuse protection relays & controls littelfuse.com/fps feeder protectionCadvanced phase voltages fps-ctu control unit relay outputs i/0 module digital inputs 4-20 ma analog input + analog output 4-20 ma + 39 40 53 52 43 51 ...... 5 16 ...... 1 2 60 56 20 17 ...... 33 22 control power rs-485 35 37 ...... 30 29 27 26 23 22 phase current tranformers ground-fault current transformer operator interface fps-opi (recommended) (required) (recommended) rtd module mps-rtd (optional) wiring diagram a b c 1 2 specifcations protective functions (ieee device numbers) input voltage 65-265 vac, 25 va; 80-275 vdc, 25 w power-up time 800 ms at 120 vac ride-through time 100 ms minimum 24-vdc source 100 ma maximum ac measurements true rms and dft, peak, 16 samples/cycle, and positive and negative sequence of fundamental frequency 50 or 60 hz inputs phase current, earth-leakage current, phase voltage, 7 digital, 1 analog output contacts 5 contacts see product manual approvals csa certifed, c-tick ( australian ) communications allen-bradley ? dfi and modbus ? rtu (standard); devicenet?, profbus ? , ethernet (optional) conformal coating standard feature warranty 10 years mounting: control unit surface operator interface panel, control-unit mounted overload (49, 51) phase reverse (current) (46) overfrequency (81) overcurrent (50, 51) underfrequency (81) ground fault (50g/n, 51g/n) unbalance (voltage) (47) rtd temperature (38, 49) unbalance (current) (46) phase loss (voltage) (47) overvoltage (59) phase loss (current) (46) undervoltage (27) phase reverse (voltage) (47) power factor (55) features & benefts features ieee # benefits overload 49, 51 long-time overcurrent provides thermal protection for feeder or load inverse-time overcurrent 50, 51 coordination using ieee and iec curves defnite-time overcurrent 50, 51 instantaneous overcurrent to detect catastrophic failure current unbalance/ phase loss/phase reverse 46 detects an open or high-impedance phase ground fault 50g/n, 51g/n inverse and defnite time. early insulation-failure detection. rtd temperature 38, 49 optional protection (mps-rtd module) for load-temperature monitoring overvoltage 59 limits stress to insulation undervoltage 27 detects a damaging brown-out condition voltage unbalance 47 detects unhealthy supply voltage two setting groups minimizes arc-flash hazards during maintenance breaker control allows local and remote operation; reduces component count metering displays the measured and calculated parameters data logging on-board 64-event recorder helps with system diagnosis communications remotely view measured values, event records, & reset trips conformal coating internal circuits are conformally coated to protect against corrosion and moisture fps series feeder protection system rev: 4-a-050213 based on manual rev 0


▲Up To Search▲   

 
Price & Availability of FPS-CTU-04-00

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X